NEC Electrical Load Calculator answers service size, feeder, branch circuit, motor and cable tray questions directly from the 2023 NEC. Every result shows the article reference, the demand factor table used and the step-by-step math, so you can check it against the code book. It's built for licensed electricians, contractors and inspectors, and it can export any result as a PDF for permits and job records.
Features
- Dwelling service sizing, standard and optional methods (NEC 220.40–220.55, 220.82)
- Commercial feeder and service loads with demand factors
- Branch circuit wire and breaker sizing with derating
- Motor conductor, overload and OCPD sizing (NEC 430)
- Panel layout and panel schedule with phase balance
- NEC article and step-by-step math on every result, plus PDF export
Calculators
Residential (dwelling units)
- Service size per NEC 220.40–220.55, standard method
- Optional method per NEC 220.82
- General lighting (3 VA/sq ft), small appliance and laundry circuits
- Fixed appliances, clothes dryer, cooking equipment and HVAC
- Table 220.42 demand factors and 230.79(C) service minimums
Commercial
- Feeder and service loads per NEC 220.12, 220.44, 220.60 and 430.24
- Lighting by occupancy type, receptacles, motors, HVAC and sign circuits
- Single-phase and three-phase, including 208 V, 480 V, 220/127 V and 440/254 V systems
Branch circuit
- Minimum conductor (AWG) and breaker size per NEC 210.19, 210.20 and Table 310.16
- Continuous load at 125%
- Conduit fill and ambient temperature derating per 310.15
- 120 V to 480 V circuits
Motor
- Conductor sizing per NEC 430.22
- Overload sizing per 430.32
- Branch circuit OCPD per 430.52 and Table 430.52
- Full-load current lookup from Tables 430.248 and 430.250 by HP, voltage and phase
Panel schedule & layout
- Generate a panel layout from a load calculation: circuit numbers, breakers, two-pole spans and spares
- Circuit-by-circuit panel schedule editor
- Phase balance, panel loading and imbalance per NEC 220.40 and 220.87
- Warns when a new circuit would overload its breaker
Cable tray
- Tray fill per NEC 392.22(A)
- Ampacity derating per 392.80(A)
- Ventilated trough and solid-bottom trays, including the 90% width rule
Reports
- NEC article citation and step-by-step math on every result
- PDF export for permit submission, job documentation and client records
Frequently asked questions
Is there an app that does an NEC residential load calculation?
Yes. NEC Electrical Load Calculator sizes the service for a dwelling unit using the NEC 2023 standard method (220.40–220.55) or the optional method (220.82). You enter floor area, appliances, dryer, cooking equipment and HVAC, and it shows the total load, the calculated current and the recommended service size, with each step's NEC reference.
How do I calculate the service size for a house, for example 100 A, 150 A or 200 A?
Add the general lighting load (3 VA per square foot), two 1,500 VA small-appliance circuits and a 1,500 VA laundry circuit, apply the Table 220.42 demand factors, then add fixed appliances, the dryer, cooking equipment and the larger of heating or cooling. Divide the total VA by the service voltage (usually 240 V) to get the current, then choose the next standard service size, never less than 100 A per 230.79(C). The app does these steps for you and shows the math.
What is the NEC 220.82 optional method?
It's a simpler way to size a single dwelling's service: the first 10 kVA of general loads is counted at 100% and the rest at 40%, then the heating or air-conditioning load is added. NEC Electrical Load Calculator lets you switch between the standard and optional methods to compare the results.
Can it size wire and breakers for a branch circuit?
Yes. The Branch Circuit module takes the continuous and non-continuous load, applies the 125% rule for continuous loads and any conduit fill or temperature derating, and gives the minimum copper or aluminum AWG and the minimum standard breaker size, per NEC 210.19, 210.20 and Table 310.16.
Does it size motor circuits per NEC Article 430?
Yes. Pick the horsepower, voltage and phase; the app looks up the full-load current in Table 430.248 or 430.250 and sizes the conductor (125% per 430.22), the overload (430.32) and the branch circuit breaker or fuse (430.52).
Does it do commercial and three-phase load calculations?
Yes. The Commercial module calculates feeder and service loads for lighting by occupancy type, receptacles (with the 220.44 demand factor), motors, HVAC and other fixed loads, on single-phase or three-phase systems such as 208 V, 480 V and 220/127 V.
Can I export the calculation for a permit?
Yes. Any result can be exported as a PDF report showing the inputs, NEC references and the step-by-step calculation, ready for permit submission or job records.
Which NEC edition does it use, and who is it for?
It uses the 2023 National Electrical Code (NFPA 70). It's made for licensed electricians, electrical contractors, engineers and inspectors. Always check results against the code edition adopted by your local authority having jurisdiction (AHJ).
Support
Need help with NEC Electrical Load Calculator? Email [email protected] and I'll get back to you.